IS
Isolator ¼±Á¤ ( Application )
|
ÇÏ´Ü¿¡¼ Àû¿ëºÐ¾ß¸¦ ¼±ÅÃÇϸé ÇØ´ç IS Isolator¿¡ ´ëÇÑ ÀڷḦ °Ë»öÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù.
|
|
|
Analogue
Input - 2¼±½Ä Àü¼Û±â (Tx) , 4-20mA Àü·ù½ÅÈ£¿ë, 'smart' ¹× 3,4¼±½Ä Àü¼Û±â |
Device
|
|
|
Output
|
LFD
|
SIL
|
HART
|
Main features
|
|
Active
|
Passive
|
Active
|
Passive
|
Splitter
|
Alarm
|
DIN-rail mounting or Termination Board available |
D5011 |
|
|
¡î
|
|
¡î
|
|
|
|
|
SIL3
|
¡î
|
12.5mm, output 550§Ù
|
D5014 |
|
|
¡î
|
¡î
|
¡î
|
¡î
|
¡î (D)
|
|
|
SIL3
|
¡î
|
12.5mm, output 550§Ù
|
D5015 |
|
|
¡î
|
¡î
|
¡î
|
¡î
|
¡î (D)
|
|
|
SIL3
|
¡î
|
12.5mm, output 550§Ù
|
D5212Q |
|
|
¡î
|
¡î (2)
|
¡î
|
|
¡î
|
¡î (1)
|
|
SIL2
|
|
22.5mm, output 300§Ù, SPDT x 1, Modbus
|
D5254S |
|
|
¡î
|
¡î
|
¡î
|
¡î
|
|
¡î (2)
|
¡î
|
SIL2
|
|
22.5mm, output 300§Ù, SPDT x 2, Modbus
|
Installation Accessories
|
D5000TB |
8 ¶Ç´Â 16 modules Termination Board, DCS system cableÀ» »ç¿ë
|
|
|
Analogue
Input - thermocouple, mV and RTD sources |
Device |
No.
of
channels |
Input from
Hazardous area
|
LFD
|
SIL
|
Output to Safe area |
Main features |
type
|
SplitterI
|
Alarm
|
DIN-rail mounting or Termination Board available |
D5072 |
1 or 2 |
mV, T/C, RTD, Ohm
|
¡î |
SIL2
|
4-20mA Source or Sink
|
¡î (D) |
1SPST photo MOS |
12.5mm, Modbus |
D5072S-087 |
1 |
2,3,4 RTD, Ohm |
¡î |
SIL2
|
2,3,4 RTD, Ohm |
|
|
12.5mm, RTD to RTD |
D5273S |
1 |
mV, T/C, RTD, Ohm
|
¡î |
SIL2
|
4-20mA Source or Sink
|
|
2SPST photo MOS |
22.5mm, Modbus |
|
|
Analogue Input - vibration transducer |
Device
|
|
Input from Hazardous area
|
LFD
|
SIL
|
Main features
|
DIN-rail mounting or Termination Board available |
D5062S |
1 |
0~ -20V@ 2,3 wire Vibration transducer |
X
|
2
|
DIP switch setting |
|
|
Analogue
Output - controller outputs, I/P converters |
Device
|
|
|
LFD
|
SIL
|
Input from Safe area
|
Main features
|
DIN-rail mounting or Termination Board available |
D5020 |
|
0/4 to 20 mA, max.700 ¥Ø load. Source
|
¡î
|
SIL2
|
4-20mA Source
|
Sourced input, Input ¡Â 2.5 V voltage drop , With HART
|
|
|
Digital
Input - switches / proximity detectors, NAMUR |
Device
|
|
|
Splitter
|
LFD
|
SIL
|
Main features
|
DIN-rail mounting or Termination Board available |
D5030 |
1 or 2
|
SPST or SPDT (relay contact) + LED
|
¡î
|
¡î
|
SIL3
|
12.5mm, 4 A 250 Vac 1000 VA, 4 A 250 Vdc 120 W
|
D5031 |
1 or 2
|
SPST open-collector TR
|
¡î
|
¡î
|
SIL3
|
12.5mm, 100 mA at 35 Vdc (¡Â 1.5 V voltage drop).
|
D5032 |
1 or 2
|
SPST or SPDT (relay contact) + LED
|
¡î
|
¡î
|
SIL3
|
12.5mm, 100 mA 50 Vdc 5 W , Termination board Use Only
|
D5034 |
1 or 2
|
Transparent Namur of input status
|
|
¡î
|
SIL3
|
12.5mm, V max. 30 V, current limited at ≈ 8 mA
|
D5036 |
1 or 2
|
SPST or SPDT (relay contact) + LED
|
|
¡î
|
SIL2
|
12.5mm, 4 A 250 Vac 1000 VA, 4 A 250 Vdc 120 W, No G3
|
D5037 |
1 or 2
|
SPST open-collector TR
|
|
¡î
|
SIL2
|
12.5mm, 100 mA at 35 Vdc (¡Â 1.5 V voltage drop)., No G3
|
D5231E |
8
|
SPST open-collector TR
|
¡î
|
¡î
|
SIL2
|
22.5mm, 100 mA at 35 Vdc (¡Â 1.0 V voltage drop), Logical output, MODBUS
|
D1130 |
1 or 2
|
SPST or SPDT (relay contact) + LED
|
¡î
|
¡î
|
SIL2
|
22.5mm, AC supply
|
|
|
Digital
Output |
Device
|
channels
|
Output to Hazardous area
|
LFD
|
SIL
|
POWER
|
Main features
|
DIN-rail mounting or Termination Board available |
D5040 |
1 or 2 |
15~17.5V/35mA(176.3§Ù~238.7§Ù),
19.5~20.5V/70mA(88.2§Ù~101.4§Ù)
|
|
SIL3 |
Loop Powered
|
24 Vdc nom (18~30Vdc) Input, 0.75 W with 24 V supply ,NE Loads
|
D5048S |
1 |
8.5~13V, 45 mA(174§Ù~275§Ù)
|
¡î |
SIL3 |
Loop Powered
|
24 Vdc nom (20~30Vdc) input, Override, 1.1 W with 24 V supply ,NE Loads
|
D5049S |
1 |
8.5~13V, 45 mA(174§Ù~275§Ù)
|
¡î |
SIL3 |
Bus Powered
|
Switch contact(5.0V ¡Â¡Ã 20.0V) input , Override, 1.1 W with 24 V supply ,NE Loads
|
D5240T |
3 |
14~17V/35 mA(176.3§Ù~278.3§Ù),
14~16V/70 mA(108§Ù~139.2§Ù),
13.5~17.5V/105mA(58.8§Ù~92.8§Ù)
|
|
SIL2 |
Bus Powered
|
Switch contact(5.0V ¡Â¡Ã 18.0V) input, 3.3 W with 24 V supply , MODBUS ,NE Loads
|
D5244 |
1 or 2 |
IS. voltage free SPDT relay contact
|
|
SIL2,3 |
Ext. Powered
|
24 Vdc nom (18~30Vdc) input, 0.4 W with 24 V supply ,NE Loads
|
|
|
Frequency
Input / RS422, RS485 Reapeater |
Device
|
|
Input
from hazardous area
|
Main features
|
DIN-rail mounting |
D1035S |
1
|
Magnetic pick-up, contact, proximity to EN60947-5-6, open collector TR to frequency signals up to 50KHz, TTL CMOS
|
22.5mm, KR type approval
|
D1060S |
1
|
RS422/ RS485 signal
|
22.5mm, Modbus, Fieldbus, Profibus and all other RS485 protocols
|
|
|
Smoke Detector / Flammable Liquid Presence Detector
|
Device |
channels |
Output to hazardous area |
Output to
Safe area
|
Main features
|
DIN-rail mounting |
D1022 |
1 or 2 |
1 to 40mA, 4-20mA output on load of 100 to 600 ohm
|
|
Input signal to Safe area : 6 to 30V loop powered, 1 to 40mA, 9.5V @ 20mA voltage drop with 500 ohm load
|
D1080D |
2 |
|
Voltage free 2 x SPDT relay contact, 2A 250Vac
|
Input from hazardouse area : 13.0V 150§Ù typical, 0 to 14mA, DIP switch settable
|
|
|
Load cell / Strain Gauge Bridge Isolating Repeater |
Device
|
No.
of
channels
|
Input from
hazardous area
|
Output to
safe area
|
SIL
|
Main features
|
DIN-rail mounting |
D5263S |
1 |
Up to 4 x 350 ohm load cell, or 5 x 450 ohm load cell, or 10 x 1,000 ohm load cells can be connected in parallel |
same as input
impedance : 500 ohm typical
Excitation voltage : ¡Ã4.0V typcial, ¡Â 15V max. Externally applied
|
SIL2
|
A/D conversion : 12.5ms
Bridge supply voltage : 4.0Vdc nominal, 1 to 4mV/V Bridge output signal
Line resistance compensation : ¡Â 10 §Ù
|
D5264S |
1 |
Up to 4 x 350 ohm load cell, or 5 x 450 ohm load cell, or 10 x 1,000 ohm load cells can be connected in parallel |
0/4-20mA on max 300 ohm load @ 24mA
Modbus RS-485
|
SIL2
|
Response time : ¡Â 20ms (10-90% step)
Bridge supply voltage : 4.0Vdc nominal, 1 to 4mV/V Bridge output signal
1x Trip Alarm SPST 100mA, 60Vdc
|
|
|