ALTEK ´ëÀÀ¸ðµ¨ mA Calibrator-334 ±¸Çü ALTEK 334A ¿¡ Àͼ÷ÇÏ´Ù¸é, ½ÅÇü°¨°¢ÀÇ PIE mA Calibrator 334¸¦ »ç¿ëÇϽʽÿÀ.
0.025% Á¤È®µµ, loop power, 250Vrms º¸È£±â´É
|
|
mA Loop Calibrator -
mACal mA Loop Calibrator·Î¼,
mA¹ß»ý,ÃøÁ¤ ¹× VoltÃøÁ¤,
24V loop power,RampÃâ·Â, Valve On/OffÁ¡°Ë, FlowÃøÁ¤¿ë Sq Root Ãâ·Âµî ±â´ÉÀÌ ÀÖ½À´Ï´Ù. |
|
mA Loop Calibrator - 530 ALTEK334A ´ëÀÀ¸ðµ¨ÀÎ mA Loop Calibrator·Î¼, mA¹ß»ý,ÃøÁ¤ ¹× VoltÃøÁ¤,Á¤¹Ð±Þ (0.012%Rdg, 1 §Ë ºÐÇØ´É)°èÃø±â ÀÔ´Ï´Ù. |
|
mA Loop Calibrator - DLC8800 mA¹ß»ý,ÃøÁ¤ ¹× VoltÃøÁ¤, Á¤¹Ð±Þ (0.015%Reading, 1 §Ë ºÐÇØ´É), mA mode¿¡¼ 250Vac protection ±â´ÉÀÌ ÀÖ½À´Ï´Ù. |
|
mA/Volt Loop Calibrator - CSC 100 mA/Volt ¹ß»ý,ÃøÁ¤ÀÌ °¡´ÉÇÑ Á¤¹Ð±Þ (0.015%Reading) , 1 §Ë ºÐÇØ´É, 24V loop power, HART,Auto Step±â´ÉÀÌ ÀÖ½À´Ï´Ù. |
|
mA / Volt Loop Calibrator - 532 mA/Voltage¹ß»ý, ÃøÁ¤, Loop Diagnostic ±â´É( leakage currentµî Loop Áø´Ü ) ¹× 24V loop power, HART,Auto Ramp, Step±â´ÉÀÌ ÀÖ½À´Ï´Ù. |
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : ±³Á¤¿¡ ´ëÇÏ¿© (±â¼úÀÚ·á). |
|
Multifunction Calibrator - ASC300 mA,
mV / Volt, T/C, RTD, Frequency,µî ¹ß»ý,ÃøÁ¤, ¾Ð·Â¸ðµâ (0.025% ¶Ç´Â 0.01% -¿É¼Ç)
ÀÌ¿ë ¾Ð·Â ÃøÁ¤
°¡´ÉÇÑ ´Ù±â´É ͏®ºê·¹ÀÌÅÍ ÀÔ´Ï´Ù. |
|
Multifunction Calibrator - APC8882 mA, mV / Volt, T/C, RTD, Frequency,µî ¹ß»ý,ÃøÁ¤, ¿É¼ÇÀÇ ¾Ð·Â¸ðµâÀ» ÀåÂøÇÏ¸é ¾Ð·Â ÃøÁ¤µµ °¡´ÉÇÑ ´Ù±â´É ÈÞ´ëÇü ͏®ºê·¹ÀÌÅÍ ÀÔ´Ï´Ù. |
|
10-50 mA / Volt Loop Calibrator - 535 4-20mA ¹× 10-50mA¹ß»ý, ÃøÁ¤
, ÇÊ¿ä½Ã 10¿È reference µµ Á¦°ø (535A) ÇÕ´Ï´Ù. 2-90V loop power
. ºÐÇØ´É 0.001ÀÇ 5 digit full display ±â´ÉÀÌ ÀÖ½À´Ï´Ù. |
|
Precision Digital Multimeter - 5075 7½Digit
Á¤¹Ð±Þ µðÁöÅÐ¸ÖÆ¼¸ÞÅÍ, °¢Á¾ ÀüÀÚÀåºñ·ù Á¤¹ÐÁ¡°Ë, µµ´Â ¼ö¸®½Ã ÇÊ¿äÇÑ Àåºñ·Î¼ 6½Digit±Þ Á¤µµÀÇ Àú·ÅÇÑ °¡°Ý´ë°¡ ÀåÁ¡.
|
|
Advanced Multi Calibrator - AMC900 ½ÇÇè½Ç±Þ Àü¾Ð,Àü·ù, T/C, RTD ¹× APM Pressure Module ¿¬°á »ç¿ë °¡´ÉÇÑ ´Ù¸ñÀû ½ÅÈ£ Ç¥ÁØ ¹ß»ý¿ø. mV, Volt, mA, T/C, RTD ¹ß»ý ¹× Á¤¹ÐÃøÁ¤±â´É, »ó´ëÀûÀ¸·Î Àú·ÅÇÑ °¡°ÝÀ¸·Î ½ÇÇé½Ç±Þ Àåºñ ±â´ÉÀ» ¹ßÈÖ ÇÕ´Ï´Ù. |
|
Freq. Calibrator - 541 (541-BNC) Frequency Calibrator·Î¼ 0.01kHz~20.000kHz Á֯ļö ¹ß»ý,ÃøÁ¤, Totalizer ±â´É ¹× BNCmodel (541-BNC) , Gate time Áö½Ã¿ë LED·¥ÇÁ¸¦ äÅÃÇÑ Frequency CalibratorÀÔ´Ï´Ù. |
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : ³ÃÁ¢Á¡±âÁØÁ¡°ú º¸»ó(Cold Junction Reference &
compensation) (±â¼úÀÚ·á). |
|
Temperature Calibrator
- CSC 200 T/C°ú RTD ¹ß»ý ¹× ÃøÁ¤,
13Á¾·ùÀÇ T/C, 14Á¾·ùÀÇ RTD ¹× mV, OhmÀ»
Áö¿ø ÇÕ´Ï´Ù.
|
|
RTD Calibrator - 512 7Á¾·ùÀÇ RTD½ÅÈ£ ¹ß»ý ¹× ÃøÁ¤, Á¤È®µµ´Â 0.25µµ¾¾,
ºÐÇØ´ÉÀº 0.1µµ¾¾. 9Vdc ¹èÅ͸®·Î
¾à 45½Ã°£ ¿¬¼Ó»ç¿ë °¡´ÉÇϸç, Pulsed type °è±â·ù Ä¿¹öÇÕ´Ï´Ù. |
|
T/C Calibrator -
522
T/C ½ÅÈ£ ¹ß»ý ¹× ÃøÁ¤,
8Á¾·ùÀÇ T/C, ¹× mV Áö¿ø, 0.008% Á¤È®µµ, 60V
overload Protection±â´É º¸À¯·Î »ç¿ëÀÚ ½Ç¼ö·Î ÀÎÇÑ ±â±âÆÄ¼Õ
¹æÁö ±â´É ³»Àå. |
|
Resistance Decade Box - 1067 RTD °ü·ÃÀåºñ·ù Á¡°Ë, ±³Á¤¿ë 6 Decade Resistance Decade Box, 0 .01% Á¤È®µµ ¹× 10 milli ohm ¿¡¼ 12,222.21 ohm ¹ß»ý
|
|
T/C Calibrator -DTC8100
T/C°ü·Ã ¹ß»ý ¹× ÃøÁ¤,
10Á¾·ùÀÇ T/C, mV±îÁö
Áö¿ø ÇÕ´Ï´Ù |
|
RTD Calibrator - MET 100 8Á¾·ù RTD½ÅÈ£ ¹ß»ý ¹× ÃøÁ¤,Á¤È®µµ 0.05µµ¾¾, ºÐÇØ´É 0.01µµ¾¾, ÃæÀü¹èÅ͸®¸¦ äÅÃÇÏ¿´À¸¸ç, Auto
Step, Ramp±â´É. |
|
Automate Temp. Calibrator - ATK ¿Âµµ±³Á¤À¸·Î ½Ã°£ ¹× ÀηÂÀÌ ¸¹ÀÌ ¼Ò¿äµÇ¾î »ùÇøµ¹æ½ÄÀ¸·Î Á¡°ËÇϽʴϱî? ÀÌÁ¨ ATK¸¦ ãÀ¸½Ê½Ã¿À !!! ½ÇÇè½Ç ±ÞÀÇ Ç¥Áؿµµ¹ß»ý ¹×
|
|
Reference Temp. Calibrator - RTC156ATK  Ç¥ÁØ±Þ ¿Âµµ ±³Á¤±â·Î¼ -46 µµ¾¾ºÎÅÍ 155µµ¾¾ Ç¥Áؿµµ ¹ß»ý±âÀÔ´Ï´Ù. (Á¤È®µµ 0.04 ~ 0.1µµ¾¾) ¾ÈÁ¤µµ 0.005µµ¾¾, ºÐÇØ´É 0.001µµ À̸ç, °¡¿Àº 17ºÐ, ÁÖº¯¿Âµµ 23µµ¾¾¿¡¼ ³Ã°¢Àº 37ºÐ Äè¼ÓÀ» ÀÚ¶û ÇÕ´Ï´Ù.
|
|
Dry Block Temp. Calibrator - CTC °ø¾÷¿ë ¿Âµµ ¹ß»ý¿øÀ¸·Î¼ º¸´Ù ½Å¼ÓÇÑ ¿Âµµ»ó½Â, Çϰ±â´É ¹× ¿Âµµ ¾ÈÁ¤µµ¸¦ Çâ»ó½ÃÄ×À¸¸ç, ¼ÒÇü °æ·®À¸·Î Á¦À۵Ǿú½À´Ï´Ù.
|
|
ÃøÁ¤Àåºñ·Î¼(0.04 ~ 0.11µµ¾¾ Á¤È®µµ), ¿Âµµ¹ß»ý°ú ÃøÁ¤ ¹× ¼·ùÇàÁ¤(ÇѱÛÈ S/W) ¹× Àü ÀÚµ¿À¸·Î ¼öÇàÇÕ´Ï´Ù. Çѱۿî¿ë ¸Å´º¾óÀ» ±âº»À¸·Î Á¦°ø ÇÕ´Ï´Ù.
¿Âµµ¹üÀ§´Â -90 ºÎÅÍ +650µµ¾¾
ÀÇ ¸ðµ¨ÀÌ ÀÖ½À´Ï´Ù.
|
|
Multi-Channel Scanner - ASM ¿©·¯°³ÀÇ ¿Âµµ¼¾¼¸¦ µ¿½Ã¿¡ °Ë,±³Á¤ÇϱâÀ§ÇÏ¿© ÇÊ¿äÇÑ ¸ÖƼä³Î ½ºÄ³³Ê ASM800À» ÀÌ¿ë 8°³ ~ÃÖ´ë 24°³ÀÇ ¿Âµµ ÇDZ³Á¤Ã¼¸¦ µ¿½Ã¿¡ ±³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù
|
|
Temp. Calibrator -TSC8802 T/C°ú RTD ¹ß»ý ¹× ÃøÁ¤ ¿ë ͏®ºê·¹ÀÌÅÍ·Î
10Á¾·ùÀÇ T/C, 8Á¾·ùÀÇ RTD ¹× YSI400
Áö¿ø. Á¤¹Ð ÈÞ´ëÇü ¿Âµµ °èÃø±â ÀÔ´Ï´Ù.
|
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : °èÀå À̾߱â (±â¼úÀÚ·á) |
|
Auto Pressure Calibrator- APC-300 -13.1 ~ 300 psi ¹üÀ§ Pneumatic ÀÚµ¿ ¾Ð·Â Á¤¹Ð ÃøÁ¤¿ë Automated Pressure Calibrator, 0.025% FS (0.01% FS option) Á¤È®µµ, 12Á¾ ´ÜÀ§º¯È¯, mA ÃøÁ¤ ±â´É. °ø±â¾Ð ÀÚµ¿ ¹ß»ý, ÃøÁ¤ ±â·Ï ¹× ¿¢¼¿½áƼ ¹ßÇàµîÀ» ¼öÇàÇÏ´Â ÀüÀÚµ¿ ¾Ð·Â °èÃø±â
|
|
nVision - Reference Press. Recorder 0 ~ 10.000 psi ¹üÀ§ pressure, mA & Volt, Ohm ÃøÁ¤ ¹× ·¹ÄÚµù (Data Logging)À» ÇÒ ¼ö ÀÖ´Â ½ÇÇè½Ç±Þ ¾Ð·Â ±â·Ï°è, 0.025% Reading Á¤È®µµ, ¼ÒÇü °æ·®ÀÇ ÈÞ´ë¿ë data logger À̸ç, À§ÇèÁö¿ª¿¡¼ »ç¿ëÇÒ ¼ö ÀÖ´Ù.

|
|
Semi Auto Electric Pump Pressure Calibrator EPC-600
Àü±â½Ä ¹ÝÀÚµ¿ °ø¾Ð ÆßÇÁ 0 ~ 1,000 psi ¹üÀ§ Pneumatic ¾Ð·Â ¹ÝÀÚµ¿ ¹ß»ý Pressure Pump, 0.05% FS ~ 0.01% FS Á¤È®µµ, mA, Voltage ÃøÁ¤ ±â´É
|
|
Handheld Press. Calibrator-HPC500 
-0.96 ~ 700 bar ¹üÀ§ ¾Ð·ÂÀ» ÃøÁ¤, ¹ß»ý, 0.025% Rdg Á¤È®µµ¿Í 15Á¾ÀÇ ´ÜÀ§º¯È¯, mA (24Vdc Loop Power), Volt, Switch µ¿ÀÛÀ» ÃøÁ¤ÇÒ ¼ö ÀÖ´Â °íÁ¤µµ, ÈÞ´ëÇü ¾Ð·Â °èÃø±â
|
|
Document Press. Calibrator - DPC -0.85 ~ 700 Kg/Cm2¹üÀ§ ¾Ð·ÂÀ» ÃøÁ¤, ¹ß»ý, 0.025% FS Á¤È®µµ¿Í 15Á¾ÀÇ ´ÜÀ§º¯È¯, mA (24Vdc Loop Power), Voltage ÃøÁ¤ ¹× Switch µ¿ÀÛÀ» Á¡°ËÇÒ ¼ö ÀÖ´Â ÈÞ´ëÇü ¾Ð·Â °èÃø±â
|
|
Precision Manometer - IS31/33 -14.7 ~ 3000 psi ¹üÀ§ ¾Ð·Â Á¤¹Ð ÃøÁ¤¿ë Ãʰ淮 ¼ÒÇüÀÇ Pressure Manometer, 0.05% Reading Á¤È®µµ,7Á¾ ´ÜÀ§º¯È¯, mA ÃøÁ¤ ±â´É. NASA ¼±Á¤Àåºñ¸ç, ¹æÆøÁö¿ª
»ç¿ë°¡´É  |
|
Gauge Comparator - GaugeCal XP 0.1% Reading Digital Gauge¿Í ÇÔ²² ½ºÅ©·ùÆßÇÁ¸¦ äÅÃ, 700Kg/Cm2 ±îÁö (¹°,±â¸§ °¡´É) ±³Á¤ÇÒ ¼ö ÀÖ´Â Gauge Comparator ·Î¼ ÆßÇÎÇϴµ¥ ¼Ó ½âÀÌÁö ¾Ê½À´Ï´Ù.
|
|
Calibration Software - FastCal XP GaugeCal Xp ¹× XP2i, 30 series Calibrator ¿ë Calibration Software ·Î¼ Pressure Gauge ±³Á¤ ¾÷¹« È¿À²À» Çâ»ó½Ãų¼ö ÀÖ½À´Ï´Ù. |
|
EEX ia µðÁöÅ» °ÔÀÌÁö - 0.1% Rdg 0.1% Reading (Temp. Compensate -10~50¡É) Á¤È®µµÀÇ Digital Test Gauge, Isolated 316SS ¼¾¼, RS232C Åë½Å, Data Logging (Hi, Lo, AvgµîÀÇ µ¥ÀÌÅÍ ±â¾ï), Dual Display ¹× ¹æÆøÁö¿ª¿ë IS ATEX ceritfied 
|
|
º¸±ÞÇü M1 µðÁöÅ» °ÔÀÌÁö - 0.2% Rdg 0.2% Reading (Temp. Compensated -10~+50¡É) Á¤È®µµÀÇ Digital Test Gauge, Isolated 316SS ¼¾¼, Backlighted Large Display (17mm), 2°³ÀÇ AA ¹ÙÅ׸®·Î ÃÖ´ë 30,000½Ã°£ ÀÛµ¿, (Ãß°¡±â´É : Hi, Lo, AvgµîÀÇ µ¥ÀÌÅÍ ±â¾ï), °ß°íÇÏ°Ô Á¦ÀÛµÇ¾î ¿¾ÇÇÑ È¯°æ¿¡¼ Áø°¡¸¦ ¹ßÈÖÇÏ´Â Àú·ÅÇÑ °ÔÀÌÁö
|
|
¾ÆÁÖ°ÇÑ ¾Æ³¯·Î±× ¾Ð·Â °ÔÀÌÁö - 3D ÇöÀå Æ¯¼º¿¡ ¾Ë¸Âµµ·Ï µðÀÚÀÎµÈ °ß°íÇÏ°í ¿À·¡ »ç¿ëÇÒ¼ö ÀÖ´Â ¾Ð·Â °ÔÀÌÁöÀÔ´Ï´Ù. Áøµ¿¿¡ °Çϵµ·Ï ¼³°èµÇ¾î Liquid Fill TypeÀ» »ç¿ëÇÒ Çʿ䰡 ¾øÀ¸¸ç inconel ÀçÁú·Î Á¦ÀÛµÈ Ç츮Į Æ©ºê´Â ºÎ½Ä¿¡µµ ¾ÆÁÖ °ÇÕ´Ï´Ù. ¶ÇÇÑ6³â ǰÁúº¸ÁõÀ» ÇàÇϰí ÀÖ½À´Ï´Ù. |
|
Dead Weight Tester - T Series ºÐµ¿½Ä ¾Ð·Â Ç¥ÁرâÀÔ´Ï´Ù. 0.1%Á¤µµºÎÅÍ 0.015% ±îÁö ÀÖÀ¸¸ç, SUS Weight¿¡ Kg/Cm2 ´ÜÀ§·Î Á¦ÀÛÇÏ¿© µå¸®°í ÀÖ½À´Ï´Ù. ¹°, °ø±â½Ä°ú ÀÇ·á¿ëµî ´Ù¾çÇÑ ¸ðµ¨ÀÌ ÀÖ½À´Ï´Ù.
|
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : ¹è¸®¾î À̾߱â 1 ¹è¸®¾î À̾߱â 2-1 ¹è¸®¾î À̾߱â 2-2 (±â¼úÀÚ·á) |
|
TMB3000 - Test Bench ½ÃÇè½Ç Ư¼º¿¡ ¾Ë¸Âµµ·Ï ¼³°èÇÒ ¼ö ÀÖ´Â ¸ðµâ¹æ½ÄÀÇ Å×½ºÆ®º¥Ä¡. Rack Type ¹× ¸ðµâÈµÈ °³°³ÀÇ °èÃø±â¸¦ Çʿ信 µû¶ó ¼Õ½±°Ô ±¸¼ºÀ» ÇÒ¼ö ÀÖÀ¸¸ç, ¹Ì·ÁÇÑ ¿Ü°ü ¹× °£Æí Á¶ÀÛ¼º, È®À强µîÀÇ Æ¯Â¡À» °®°í ÀÖ½À´Ï´Ù.
|
|
RH,Dewpoint ¹×Temp Transmitter - HTZ °øÀå, Á¦¾à, ½ÇÇè½Ç, °¢Á¾ »ý»ê¶óÀÎÀÇ »ó´ë ½Àµµ¹×, ³ëÁ¡¿Âµµ ±×¸®°í ¿ÂµµµîÀ» Á¤¹ÐÇÏ°Ô ÃøÁ¤ÇÏ¿©, 4-20mA ¹× HART ½ÅÈ£·Î Àü¼ÛÇØ ÁÖ´Â »ó´ë½Àµµ HART Àü¼Û±â ÀÔ´Ï´Ù.
|
|
IR Temp. Sensor - PyroBus  Infra Red Temperature Sensor ·Î¼ -20 ~ 500µµ¾¾ ¿Âµµ¸¦ ÃøÁ¤ÇÏ¿© RS485 Åë½ÅÀ» ÀÌ¿ë ¿ø°Ý¿¡¼ Monitoring Çϰųª PLC, DCS¿¡ ¿¬°á°¡´ÉÇÑ Àû¿Ü¼± ¿Âµµ ¼¾¼ ½Ã½ºÅÛ, ÃÖ´ë 32 ¼¾¼ / RS485 Modbus RTU ¶Ç´Â 8´ë / display
|
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : Remote I/O 8000 System -1 Remote I/O 8000
System -2
(±â¼úÀÚ·á) |
|
Universal Temp.Transmitter-2800T Universal Input HART Temperature Transmitter·Î¼, 7 T/C, 6 RTD, mV, OhmµîÀ» ÀÔ·Â¹Þ¾Æ 4-20mA½ÅÈ£·Î Àü¼Û, Full 5 digit display ¹× 0.05% digital Accuracy,
built-in two button configuration Á¦Ç°À¸·Î¼ ±¹³»¿¡ ¸¹ÀÌ º¸±ÞµÈ Best Seller ǰ¸ñ ÀÔ´Ï´Ù |
|
mini-Signal Isolator - MIX & MIT  ÇöÀå¿¡¼ °¢Á¾ ¿Ü¶õ, Àü¿øÃæµ¹, Á¢Áö¿µÇâµîÀ¸·Î °í»ýÇϰí Àְųª, Ãâ·Â½ÅÈ£ ºÐ¹è°¡ ÇÊ¿äÇÏ½Ã´Ù¸é ½ÅÈ£ºÐ¸®±â¸¦ »ç¿ëÇϽñ⠹ٶø´Ï´Ù. Æø 25.4mm¿¡ ÃÖ´ë 4ä³Î±îÁö ½ÅÈ£ºÐ¸®, ½ÅÈ£º¯È¯À» ÇÒ ¼ö ÀÖ½À´Ï´Ù. (ÆÄ³Ú¾÷ü¿¡ °·ÂÃßõ)
|
|
Signal Isolator - ECT ÇöÀå¿¡¼ °¢Á¾ ¿Ü¶õ, Àü¿øÃæµ¹, Á¢Áö¿µÇâµîÀ¸·Î °í»ýÇϰí Àְųª, Ãâ·Â½ÅÈ£ ºÐ¹è°¡ ÇÊ¿äÇÏ½Ã´Ù¸é ½ÅÈ£ºÐ¸®±â¸¦ »ç¿ëÇϽñ⠹ٶø´Ï´Ù. 2Wire, 4Wire¸¦ Áö¿øÇÕ´Ï´Ù. |
|
HART I/F & Monitor - HIM ÇöÀå¿¡ Smart °è±â¸¦ »ç¿ëÇϽʴϱî? HART I/F & Monitor¸¦ Signal Line¿¡ º´¿·Î ¿¬°á¸¸ ÇϽøé ÇØ´ç Smart °è±âÀÇ ¸ðµç ÀåÁ¡À» ÀÌ¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ÁøÁ¤ÇÑ HART ±â´ÉÀ» ÀÌ¿ëÇÏ¿© ÇÁ·Î¼¼½º ¿îÀüÈ¿À²À» ¿Ã¸± ¼ö ÀÖ½À´Ï´Ù. Ãâ·ÂÀº 2 AO (¿É¼Ç: 3AO), ¹× 2 Á¢Á¡À» µ¿½Ã Ãâ·Â½Ãų ¼ö ÀÖ´Â ¸ðµ¨ °ú MODBUS 2Ãâ·Â (¿É¼Ç 1 AO) ¸ðµ¨ |
|
MODBUS I/F - TMZ ÇÁ·Î¼¼½º ÇöÀå¿¡¼ °èÀå½ÅÈ£¸¦ Modbus ½ÅÈ£·Î º¯È¯ÇÏ¿©¾ßÇÒ Çʿ䰡 ÀÖÀ¾´Ï±î? MODBUS Converter TMZ·Î T/C, RTD, mA, Voltage µîÀÇ ½ÅÈ£¸¦ Host System¿¡ ¸®ÇÇÅÍ ¾øÀÌ 32´ë±îÁö ¿¬°áÇÒ ¼ö ÀÖ½À´Ï´Ù. MODBUS I/F Àåºñ·Î ½Ã½ºÅÛ ¹× ÇöÀå½ÅÈ£ ¿îÀüÈ¿À²À» ¿Ã¸± ¼ö ÀÖ½À´Ï´Ù. |
|
SIL2 Safety Trip Alarm - STA  ÇöÀå¿¡¼ ÇÁ·Î¼¼½ºÀÌ»ó °¨½Ã°¡ ÇÊ¿äÇÒ °æ¿ì »ç¿ëÇÏ´Â ¹ü¿ëÀÔ·ÂÀÇ ÇöÀå ÇÁ·Î±×·¥Å¸ÀÔÀÇ SIL2 Compliant ¾Ë¶÷ ¸ð´ÏÅÍ ½ºÀ§Ä¡ÀÔ´Ï´Ù. (½ÅÇü)
ÃÖ´ë 2+1Á¢Á¡±îÁö Ãâ·Â½Ãų ¼ö ÀÖÀ¸¸ç, ¿É¼ÇÀ¸·Î 4-20mA¾Æ³¯·Î±× ½ÅÈ£µµ µ¿½Ã Ãâ·Â½Ãų ¼ö ÀÖ½À´Ï´Ù.
|
|
Universal Alarm Monitor S/W-SPA2 ÇöÀå¿¡¼ ÇÁ·Î¼¼½ºÀÌ»ó °¨½Ã°¡ ÇÊ¿äÇÒ °æ¿ì »ç¿ëÇÏ´Â ¹ü¿ëÀÔ·ÂÀÇ ÇöÀå ÇÁ·Î±×·¥Å¸ÀÔÀÇ ¾Ë¶÷ ¸ð´ÏÅÍ ½ºÀ§Ä¡ÀÔ´Ï´Ù. (½ÅÇü)
ÃÖ´ë 4Á¢Á¡±îÁö Ãâ·Â½Ãų ¼ö ÀÖÀ¸¸ç, ¿É¼ÇÀ¸·Î 4-20mA¾Æ³¯·Î±× ½ÅÈ£µµ µ¿½Ã Ãâ·Â½Ãų ¼ö ÀÖ½À´Ï´Ù. |
|
Universal Temp. Transmitter - TDY ¹ü¿ë ÀÔ·Â ¿ÂµµÀü¼Û±â(Temperature Transmitter)·Î¼, 9T/C, 22RTD, mV, OhmµîÀ» ÀÔ·Â¹Þ¾Æ 4-20mA½ÅÈ£·Î Àü¼ÛÇÕ´Ï´Ù. ƯÈ÷ 4wire RTD´Ü¼±±îÁö °ËÃâÇϸç, ÇöÀå°ú DCS, ÆÐ³Î°úÀÇ Loop Test¸¦ À§ÇÏ¿© ÇöÀçÀÇ PVÄ¡ ¹× Àü¼Û mAÄ¡¸¦ µ¿½Ã¿¡ Ç¥½ÃÇϹǷΠLoop Calibrator°¡ ÇÊ¿ä ¾ø½À´Ï´Ù. |
|
I/P Convertor - IPH DCSÀåºñ³ª ÆÐ³ÎÀåºñ·ÎºÎÅÍ 4~20mA°èÀå½ÅÈ£¸¦ ¹Þ¾Æ 0.2-1Kg/Cm2À¸·Î º¯È¯ÇÏ¿© ÁÖ´Â º¯È¯±â·Î¼ ³»È¯°æ¼º, ³» Áøµ¿¼º µîÀÌ ¶Ù¾î³ Á¦Ç°ÀÔ´Ï´Ù. |
|
º¸±ÞÇü, Signal Isolator- Output Loop Power ÇöÀå¿¡¼ °¢Á¾ ¿Ü¶õ, Àü¿øÃæµ¹, Á¢Áö¿µÇâµîÀ¸·Î °í»ý Çϰí ÀÖ½À´Ï±î . Ouput Loop Powered ¾ÆÀַ̼¹ÀÌÅ͸¦ ¼Ò°³ ÇÕ´Ï´Ù. |
|
º¸±ÞÇü, Signal Isolator- Input Loop Power ÇöÀå¿¡¼ °¢Á¾ ¿Ü¶õ, Àü¿øÃæµ¹, Á¢Áö¿µÇâµîÀ¸·Î °í»ý Çϰí ÀÖ½À´Ï±î . Input Loop Powered ¾ÆÀַ̼¹ÀÌÅ͸¦ ¼Ò°³ ÇÕ´Ï´Ù |
|
Signal Isolator - SCT302 ÇöÀå¿¡¼ °¢Á¾ ¿Ü¶õ, Àü¿øÃæµ¹, Á¢Áö¿µÇâµîÀ¸·Î °í»ýÇϰí Àְųª, Ãâ·Â½ÅÈ£ ºÐ¹è°¡ ÇÊ¿äÇÏ½Ã´Ù¸é ½ÅÈ£ºÐ¸®±â¸¦ »ç¿ëÇϽñ⠹ٶø´Ï´Ù. 3Wire¸¦ Áö¿øÇÕ´Ï´Ù. |
|
AC Volt/I Transmitter - ACX240 0-5Aac, 250Vac ½ÅÈ£¸¦ ÀÔ·Â¹Þ¾Æ 4-20mA ½ÅÈ£·Î Àü¼Û ÇÏ´Â 2 wire loop power AC Àü¼Û±âÀÔ´Ï´Ù.
|
|
RTD Temp.Converter - RBT-372 2, 3, 4wire RTD ½ÅÈ£¸¦ ÀÔ·Â¹Þ¾Æ 4-20mA, 1-5Vdc ½ÅÈ£·Î º¯È¯ÇÏ´Â ½ÅÈ£ º¯È¯±â·Î¼ 110 msec ÀÀ´ä¼Óµµ·Î ºü¸¥ ¿Âµµ º¯ÈÀ²À» ÃøÁ¤ Àü¼ÛÇϴ Ư¡À» °®Àº RTD ¿Âµµ º¯È¯±âÀÔ´Ï´Ù. (3 wire powered )
|
|
T/C Temp.Converter - TCT-327 11 T/C ½ÅÈ£¸¦ ÀÔ·Â¹Þ¾Æ 4-20mA, 1-5Vdc ½ÅÈ£·Î º¯È¯ÇÏ´Â ½ÅÈ£ º¯È¯±â·Î¼ 67 msec ÀÀ´ä¼Óµµ·Î ¾ÆÁÖ ºü¸¥ ¿Âµµ º¯ÈÀ²À» ÃøÁ¤ Àü¼ÛÇϴ Ư¡À» °®Àº T/C ¿Âµµ º¯È¯±âÀÔ´Ï´Ù. (3 wire powered )
|
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : Networked I/O Vision 4300 System
(±â¼úÀÚ·á) |
|
Fieldbus Indicator - BEKA 
Fieldbus ¿ë Indicator, displayÀÔ´Ï´Ù. ÇöÀå»óȲ¿¡ ¸Âµµ·Ï ÀϹÝÁö¿ª¿ë, Zone 2¿ë ¹× Instrinsic Safe¿ë¿¡ »ç¿ëÇÒ ¼ö ÀÖ´Â Á¦Ç°ÀÔ´Ï´Ù.
ÇöÀå¿¡ ¼³Ä¡ÇÒ ¼ö ÀÖ´Â IP66¿ë GRP ¹×, ÆÇ³Ú¿ëÀ¸·Î ±¸ºÐµÇ¾î ÀÖ½À´Ï´Ù.
|
|
475 Field Communicator HART, Foundation Fieldbus °ü·Ã ÇöÀåÀÛ¾÷ÀÌ ÇÊ¿äÇÒ ¶§ »ç¿ëÇÏ´Â ÈÞ´ë¿ë Field CommunicatorÀÔ´Ï´Ù. Touch Screen ±â´ÉÀÇ Color LCD¸¦ äÅÃÇÏ¿©, ¿î¿ë´É·ÂÀ» Çâ»ó½ÃÄ×À¸¸ç, ¹æÆøÁö¿ª¿¡¼ »ç¿ëÇÒ ¼ö ÀÖ´Â Intrinsic Safety ceritified ÀåºñÀÔ´Ï´Ù.
HART, Foundation Fieldbus ¼³Ä¡, ½Ã¿îÀü, À¯Áöº¸¼ö¿¡ ²À ÇÊ¿äÇÑ °èÃø±â ÀÔ´Ï´Ù. |
|
Fieldbus Test Equipments Fieldbus °ü·Ã ÄÉÀÌºí »óÀÇ Fieldbus ½ÅÈ£À¯¹«, Àü¾Ð»óÅÂ, ³ëÀÌÁî ¹× °¨¼â·®, ¹Ý»çÆÄµîÀ» ÃøÁ¤ÇÏ¿© Fieldbus ¼±·Î ¹× °ü·Ã Àåºñ·ùÀÇ »óŸ¦ Á¡°ËÇÒ ¼ö ÀÖ¾î ¼³Ä¡, ½Ã¿îÀü, À¯Áöº¸¼ö¿¡ ²À ÇÊ¿äÇÑ °èÃø±â ÀÔ´Ï´Ù. |
|
FISCO Fieldbus Power - NET9000 FISCO Çʵå¹ö½º¿ë Àü¿ø½Ã½ºÅÛÀ¸·Î¼, Isolation conditioning circuitÀ» »ç¿ë two earth fault»óȲ¿¡¼µµ ¾ÈÀüÇϸç, repeater, terminator µîÀ» ³»ÀåÇϰí ÀÖÀ¸¸ç DIP switch¸¦ ÀÌ¿ë ¼±ÅÃÇÒ ¼ö ÀÖ½À´Ï´Ù. (FISCO certification fieldbus power supply) |
|
Fieldbus Power System - FPS-I Çʵå¹ö½º¿ë Àü¿ø½Ã½ºÅÛÀ¸·Î¼, ÀÌÁßÈÀü¿øÀ̸ç, Çʵå¹ö½º¿¡ ¿µÇâ¾øÀÌ Àü¿ø±³Ã¼°¡ °¡´ÉÇϸç, Àü¿ø¸ðµâÀÌ»ó, Çʵå¹ö½º ÄÉÀÌºí ´Ü¶ô (Short Circuit)µîÀÇ ÀÌ»ó»óŸ¦ ¿ø°Ý½Ã½ºÅÛ¿¡¼ °¨½Ã °¡´ÉÇÕ´Ï´Ù. |
|
Fieldbus Surge Protector - FP32 Çʵå¹ö½º¿ë ½áÁö º¸È£±â·Î¼ Çʵå¹ö½º ½Ã½ºÅÛ, Å͹̳×ÀÌÅÍ, ½ºÆÛºí·ÏµîÀ» ÁÖº¯ÀÇ ³«·Ú, À¯µµ·Ú, ¿Ü¶õµîÀ¸·ÎºÎÅÍ º¸È£ÇØÁÖ´Â Fieldbus, Profibus-PA, WorldFTI Àü¿ë Surge Protector·Î¼, ¿ë·®Àº 20kA ÀÔ´Ï´Ù. |
|
Fieldbus Junction Box - FB-JBxx Çʵå¹ö½º¿ë Á¤¼Ç¹Ú½º·Î¼ Fieldbus Surge Protector, MEGABLOCK, Device coupler, Terminator¸¦ ±Ô°Ý¿¡ ¸Â°Ô ¼³°è Á¦ÀÛµÈ 316 stainless steel ÀçÁúÀÇ FF field connection device ·Î, SIRA, ATEX ¹× UL certificate µî ½áƼ ȹµæ Á¦Ç°À¸·Î, ¼³°è, Á¦ÀÛ, ±â´ÉÅ×½ºÆ®,FAT¸¦ ¿Ï·áÇÑÈÄ ÀεµÇص帮¹Ç·Î ÇöÀå¿¡ ¹Ù·Î ¼³Ä¡ ¿îÀüÀÌ °¡´ÉÇÕ´Ï´Ù.
|
|
IS Barrier - MTL»ç ¹è¸®¾î º»Áú¾ÈÀü¹æÆø ¹è¸®¾î·Î¼, °æÁ¦ÇüÀÎ ¼ÇÆ®Á¦³Ê ¹è¸®¾î, ½Ã½ºÅÛÀ¯¿¬¼ºÀ» °í·ÁÇÑ 4000½Ã¸®Áî ¹× ¼³Ä¡¸éÀûÀ» ÃÖ¼ÒÈÇÑ 5000½Ã¸®Áî°¡ ÀÖ½À´Ï´Ù. ½Ã½ºÅÛ µðÀÚÀνà ¹Ì·¡¸¦ »ý°¢ÇϽŴٸé, ¼¼°èÃÖ°í±â¼úÀ» ÀÚ¶ûÇÏ´Â MTL»çÀÇ ¹è¸®¾î, IS Isolator¸¦ ¼±ÅÃÇϽñ⠹ٶø´Ï´Ù. |
|
Surge Protection Device-MTL ÀÌÀ¯¾øÀÌ Ç÷£Æ®°¡ ¼Ë´Ù¿î µÇ°Å³ª, °¢Á¾ ÀåºñÀÇ holding, resetµîÀÇ Çö»óÀÌ ÀÚÁÖ ¹ß»ý Çմϱî? ±×·¸´Ù¸é, ½áÁö¸¦ Çѹø °í·ÁÇÏ¿© º¸½Ã±â ¹Ù¶ø´Ï´Ù. ƯÈ÷ ´ëÇüÄÄǪ·¹¼, Åͺó,Àü¿ø¼ºê½ºÅ×À̼Ç, Àü±â·ÎµîÀ» »ç¿ëÇÏ´Â Ç÷£Æ®ÀÇ ¿îÀü ½Å·Ú¼ºÀ» Çâ»ó½ÃÄÑ µå¸± »Ó¸¸ ¾Æ´Ï¶ó Àåºñ¼ö¸í, MTBFµîÀ» ´Ã·Á µå¸³´Ï´Ù. |
|
MOST
°³¹æÇü ÄÁÆ®·Ñ½Ã½ºÅÛÀ» ãÀ¸½Ê´Ï±î? MOST systemÀ» äÅÃÇϽʽÿÀ. Dual Redundant Controller, IsaGRAF¸¦ äÅà ¼Õ½±°Ô configuration ÇÒ ¼ö ÀÖÀ¸¸ç, Ethernet, MODBUS, PROFIBUS, HART pass thru ±â´É ¹× Zone 1 Div 1¿¡ ¼³Ä¡°¡´ÉÇÑ ½Ã½ºÅÛ ÀÔ´Ï´Ù.
|
|
|
|
|
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : Çʵå¹ö½º ÇöÀå½Ç¹« (±â¼úÀÚ·á) |
|
Insulation Tester Calibrator -5069 ÃÖ´ë 10kV Insulation Tester¸¦ °Ë,±³Á¤ÇϱâÀ§ÇÑ Insulation Tester Calibrator·Î¼ 0-10kV, 0-20mA±îÁö ±³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. |
|
15ppm Multifunction Calibrator - 5025 Àü·Â
Àåºñ·ù °Ë, ±³Á¤¿ë ½Å°³³äÀÇ 15 ppm Á¤¹ÐµµÀÇ 1050Vac/dc, 22Adc/ac, 1Gohm, Inductance, Capacitance ¹× Oscilloscope, Clamp on meter ±³Á¤µîÀ» À§ÇÑ Á¤¹Ð±Þ 22bit resolutionÀÇ ´Ù±â´É ½ÅÈ£ ¹ß»ý±â |
|
Ductor Calibrator - 5070 Ductor Tester, Micro,Milli-ohm meterµîÀ» ±³Á¤Çϱâ À§ÇÑ Ductor CalibratorÀÔ´Ï´Ù. 0.2 ~ 2000 Milli-Ohm¿ë 3A ~ 200A ac/dc Current¸¦ Áö¿ø ÇÕ´Ï´Ù. |
|
Calibration Station - 5051 Á¤¹Ð±Þ ÀüÀÚÀåºñ·ùÀÇ Á¡°Ë, ±³Á¤ ¼ö¸®µîÀ» À§ÇÑ 1KVac/dc, 22Adc/ac, 1GohmÀúÇ×,Inductance, Capacitance, FrequencyµîÀÇ ½ÅÈ£¹ß»ý, ÃøÁ¤ÀÌ °¡´ÉÇÑ 0.25ppm resolutionsÀÇ Á¾ÇÕ °èÃø ½ºÅ×ÀÌ¼Ç ÀÔ´Ï´Ù.
|
|
Oscilloscope,Counter
& Timer Calibrator-5041 ¿À½Ç·Î½ºÄÚÇÁ,
Ä«¿îÅÍ ¹× ŸÀÌ¸Ó µîÀ» °Ë,±³Á¤ÇϱâÀ§ÇÑ °èÃø±âÀÔ´Ï´Ù. ½ºÄÚÇÁ´Â 600MHZ±îÁö,
±×¸®°í Ä«¿îÅÍ ¹× ŸÀ̸Ӵ 1GHz ±îÁö Á¤¹Ð ±³Á¤ÀÌ °¡´ÉÇÕ´Ï´Ù |
|
3ch Precision Power
Supply - 5033 Á¤¹Ð
ÀüÀÚÀåºñ·ù ¼ö¸®¸¦ À§ÇÏ¿© Á¤¹Ð±Þ DC Àü¿øÀÌ ÇÊ¿äÇϽʴϱî? µ¶¸³µÈ
0-22V, 2A 40Watt, 3Ch Precision Power Supply¸¦ »ç¿ëÇØ º¸½Ã±â
¹Ù¶ø´Ï´Ù. |
|
Àá½Ã ½¬¾î°¡´Â ÄÚ³Ê : HART Connection System HART Monitor Devices
(±â¼úÀÚ·á) |